DIY Builds
Photo by Scott Spedding Pexels Logo Photo: Scott Spedding

Can armoured cable be buried in soil?

Armoured cables and cables having an earthed metal sheath suitable for use as a protective conductor may be buried directly in the ground without further protection, except against corrosion, which may be negated by the provision of a plastic covering.

Does a porch need to be insulated?
Does a porch need to be insulated?

A temperature-regulated porch can add value to your home in real estate. It prevents the porch from overheating in the summertime. Insulation keeps...

Read More »
What education is required to be a woodworker?
What education is required to be a woodworker?

To be certified as a Carpenter, you usually need to complete a four-year apprenticeship program. Once you successfully complete the required on-...

Read More »
Can I build my own shed?
Can I build my own shed?

Yes, with the right plans you can build your dream shed.

Learn More »

Elecsa offer support and guidance for electrical garden installations.

Electrical installations installed in a garden, including luminaires and their associated cables, should be securely fixed and protected against accidental damage and attack by rodents. Surface-fixed cables should be fixed to permanent structures only and should be supported at sufficient height above the ground to avoid accidental contact with footwear and garden tools. All equipment, including luminaires, must be designed for use outdoors and be installed in accordance with the manufacturer’s instructions. The use of Class II equipment is conducive to electrical safety and is encouraged. There is no specific section in Part 7 of BS 7671 for installations in gardens. However, the particular requirements of Section 705 apply to agricultural and horticultural premises and should be used for guidance. The risk of a fatal electric shock is increased when persons have good electrical contact with Earth. To reduce the risks associated with the use of electricity socket-outlets must have additional protection in the form of a 30 mA RCD with a rated residual operating current (I∆n) not exceeding 30 mA and an operating time not exceeding 40 ms at a residual current of 5 I∆n in the event of failure of the provision for basic protection and/or the provision for fault protection or carelessness by users.

Buried cables

Where it is decided that cables will be buried in the ground, the cables should be routed such that they are not likely to be damaged by any foreseeable disturbance and should be buried at sufficient depth (normally taken as not less than 600 mm). All buried cables should be marked by cable covers or marker tape as shown in Fig 1 (Regulation 522.8.10 refers). Non-armoured buried cables should be installed in a conduit or suitable duct to provide protection against impact. Armoured cables and cables having an earthed metal sheath suitable for use as a protective conductor may be buried directly in the ground without further protection, except against corrosion, which may be negated by the provision of a plastic covering.

Surface fixed cables

Surface fixed cables may be fixed to permanent structures. Timber fencing is not considered to be suitable for supporting cables, for reasons which may include the following:

wood preservatives may attack the cable sheath (Regulation Group 522.5 refers)

timber fencing is unlikely to be sufficiently rigid (Regulation 522.8.5 refers)

the life of timber fencing is likely to be less than that of the cable (Regulation 522.8.1 refers)

How do I run electric cable in my garden?
How do I run electric cable in my garden?

How Do I Get The Electricity Running To My Garden Building? In short, an armoured cable has to be connected directly from your main house supply to...

Read More »
Is it best to lay slabs on sand or cement?
Is it best to lay slabs on sand or cement?

Sand is popular because it holds just as firmly as cement, while still allowing for the easy escape of water through your patio slabs. May 13, 2022

Read More »

damage sustained by the fence due to the high winds (may present a risk of electric shock)

(Regulation 522.7.1 refers).

Socket-outlets

Surface fixed cables should not be exposed to prolonged sunlight unless they are a suitable type. Black thermoplastic (PVC) cable sheaths contain carbon black which resists the effects of sunlight. White or grey cable sheaths are likely to deteriorate with prolonged exposure to the sun and should always be shielded (Regulation 522.11.1 refers). Provided they are designed for outdoor use, 13 A socket-outlets to BS 1363 may be installed in a garden as a convenient way of connecting luminaires and other equipment. 13 A socket-outlets installed in a garden must either incorporate a 30 Ma RCD or be supplied from a circuit provided with additional protection by a 30 mA RCD (Regulation 411.3.3 refers). Whilst for household installations, only shuttered socket-outlets should be used (see Regulation 553.1.201), industrial socket-outlets including plugs, connectors and appliance inlets complying with BS EN 60309-2 may be used in locations outside of the dwelling where appropriate. Socket-outlets should not be installed in a position where they may be damaged by a lawn mower, hedge trimmer or other garden tools. Equipment may need to be so placed that they are not directly exposed to the effects of the weather, or be placed within an appropriately weatherproof enclosure. Fig 2 shows a SRCD in such an enclosure.

Ponds

Only special equipment and submersible cables designed for use in ponds should be used. Risk of damage to equipment and cables will be minimised by careful positioning and routing of cables. Cables may need additional protection against accidental damage and attack by rodents. All equipment located close to a pond should be protected against ingress of water and resistant to corrosion. Pond pumps should comply with BS EN 60335-2-41. Pond lighting should comply with BS EN 60598-2-16. Other equipment for ponds should comply with BS EN 60335-2-55. Electrical installations associated with large ponds, which could be used for bathing, should comply with the additional requirements for swimming pools. Section 702 of BS 7671 refers. For more detail on installing electrical equipment outside of the dwelling, please visit www.elecsa.co.uk

Is a home office a good investment?
Is a home office a good investment?

Recent research suggests that adding a home office to your property can increase its worth by as much as 10%! May 24, 2021

Read More »
What is better fiber mesh or rebar?
What is better fiber mesh or rebar?

Polymer fiber reinforcement offers better corrosion resistance compared to steel reinforced concrete. Apr 20, 2021

Read More »
Can I build my own shed?
Can I build my own shed?

Yes, with the right plans you can build your dream shed.

Learn More »
How much does it cost to build a 12x24 storage building?
How much does it cost to build a 12x24 storage building?

Average Cost to Build a Simple Shed (Shell) Average Cost to Build a Simple Shed (Shell) 20x20 Shed Price $1,500 $4,000 Cost to Build a 10x10 Shed...

Read More »
How long do Amish sheds last?
How long do Amish sheds last?

20 to 30 years While the answers differ dramatically depending on the quality, our Amish sheds last 20 to 30 years, if not longer! However,...

Read More »