So for your first question: no, it is not against code to install a ground rod at the subpanel. It is actually required by code.
2022 will remain a strong sellers' market Despite this month's seasonal price fall, we expect asking prices to rise by another 5% in 2022. However,...
Read More »
2: For dryers that are located in a place where venting to the outside is difficult, it's OK to simply vent the dryer into a container of water....
Read More »To make this easier, consider the grounding conductor (the ground wire) as a backup neutral. It's not used unless a ground fault occurs, in which case it's only purpose is to provide a path back to the source so that a protective device will trip. (breaker, fuse, etc.) Your grounding electrode system on the other hand, the ground rod here, is only used for over-voltages on the line such as static or potentially lightning. Although we bond the grounding system, they serve two different purposes. So for your first question: no, it is not against code to install a ground rod at the subpanel. It is actually required by code. NEC 2014 - 250.32(A) Grounding Electrode. Building(s) or structure(s) supplied by feeder(s) or branch circuit(s) shall have a grounding electrode or grounding electrode system installed in accordance with Part III of Article 250. The grounding electrode conductor(s) shall be connected in accordance with 250.32(B) or (C). Where there is no existing grounding electrode, the grounding electrode(s) required in 250.50 shall be installed. The only exception to that being that if you were only running a single circuit (or multiwire branch circuit) with a ground wire, then you would not need an electrode system. Now on to your next question on if a metal stake/metal building works as an electrode: yes and no. There are a few conditions were these could apply, but they do have to have direct contact to the ground (the earth itself, the dirt or concrete below). Check out 250.52 (NEC 2014) for the list of electrodes that can be used. Lastly, all new feeders to outbuildings must contain a ground wire. Previously they were not required, but this is no longer legal or up to code for new installations. However, modifications to existing 3-wire systems do not require the pulling of a new ground wire as long as it fits a few requirements for the exception; as seen in 250.32(B) (NEC 2014)
A metal shed is great for those who need a cost-effective, simple storage solution. If you do not want or need custom features and simply want to...
Read More »
Understanding the Minimum Roof Pitch International building code guidelines recommend a minimum roof pitch of 1/4:12. This means that for every 12...
Read More »
Polystyrene Fact Sheet: 8 reasons to ban Styrofoam It is a 'known hazardous substance. ... It leaches into food and drink. ... It's in the air and...
Read More »
Luckily, there are some great options for lighting up your shed! You can use natural light by installing a window, skylight or sun tube to brighten...
Read More »
Best wood preservative for sheds ranked by strength and price [Summer 2021] Cuprinol 5 Star Complete Wood Treatment. Everbuild EVBLJCR05 wood...
Read More »
Average Two Car Garages Typically, two car garages are 18 feet wide by 20 feet deep. This is just enough to fit two cars in your garage. There are...
Read More »