Does armoured cable need to be buried in conduit?

Armoured cables and cables having an earthed metal sheath suitable for use as a protective conductor may be buried directly in the ground without further protection, except against corrosion, which may be negated by the provision of a plastic covering.

What are the best plants for pots all year round?
What are the best plants for pots all year round?

Best plants for pots all year-round Skimmia japonica. Hosta. Fountain grass (Pennisetum setaceum) Buddleia 'Buzz' Hebe. Agapanthus. Cornus....

Read More »
Do I need Vapour barrier with Celotex?
Do I need Vapour barrier with Celotex?

Celotex does need a vapour barrier, as a vapour barrier will help to prevent moisture and air from seeping through the wallboard and into the...

Read More »

Elecsa offer support and guidance for electrical garden installations.

Electrical installations installed in a garden, including luminaires and their associated cables, should be securely fixed and protected against accidental damage and attack by rodents. Surface-fixed cables should be fixed to permanent structures only and should be supported at sufficient height above the ground to avoid accidental contact with footwear and garden tools. All equipment, including luminaires, must be designed for use outdoors and be installed in accordance with the manufacturer’s instructions. The use of Class II equipment is conducive to electrical safety and is encouraged. There is no specific section in Part 7 of BS 7671 for installations in gardens. However, the particular requirements of Section 705 apply to agricultural and horticultural premises and should be used for guidance. The risk of a fatal electric shock is increased when persons have good electrical contact with Earth. To reduce the risks associated with the use of electricity socket-outlets must have additional protection in the form of a 30 mA RCD with a rated residual operating current (I∆n) not exceeding 30 mA and an operating time not exceeding 40 ms at a residual current of 5 I∆n in the event of failure of the provision for basic protection and/or the provision for fault protection or carelessness by users.

Buried cables

Where it is decided that cables will be buried in the ground, the cables should be routed such that they are not likely to be damaged by any foreseeable disturbance and should be buried at sufficient depth (normally taken as not less than 600 mm). All buried cables should be marked by cable covers or marker tape as shown in Fig 1 (Regulation 522.8.10 refers). Non-armoured buried cables should be installed in a conduit or suitable duct to provide protection against impact. Armoured cables and cables having an earthed metal sheath suitable for use as a protective conductor may be buried directly in the ground without further protection, except against corrosion, which may be negated by the provision of a plastic covering.

Surface fixed cables

Surface fixed cables may be fixed to permanent structures. Timber fencing is not considered to be suitable for supporting cables, for reasons which may include the following:

wood preservatives may attack the cable sheath (Regulation Group 522.5 refers)

timber fencing is unlikely to be sufficiently rigid (Regulation 522.8.5 refers)

the life of timber fencing is likely to be less than that of the cable (Regulation 522.8.1 refers)

Will a porch light keep raccoons away?
Will a porch light keep raccoons away?

Although a porch light is helpful, it will not keep every raccoon away because the light source is too high. Motion-activated floodlights are lower...

Read More »
Do metal garages add value to a home?
Do metal garages add value to a home?

Most realtors believe that a metal garage can add significant value to a home's value, up to $30,000 for a two-car detached or attached garage, and...

Read More »
Are shed plans easy to follow?
Are shed plans easy to follow?

These are! They guide you every step of the way to complete your dream shed.

Learn More »

damage sustained by the fence due to the high winds (may present a risk of electric shock)

(Regulation 522.7.1 refers).

Socket-outlets

Surface fixed cables should not be exposed to prolonged sunlight unless they are a suitable type. Black thermoplastic (PVC) cable sheaths contain carbon black which resists the effects of sunlight. White or grey cable sheaths are likely to deteriorate with prolonged exposure to the sun and should always be shielded (Regulation 522.11.1 refers). Provided they are designed for outdoor use, 13 A socket-outlets to BS 1363 may be installed in a garden as a convenient way of connecting luminaires and other equipment. 13 A socket-outlets installed in a garden must either incorporate a 30 Ma RCD or be supplied from a circuit provided with additional protection by a 30 mA RCD (Regulation 411.3.3 refers). Whilst for household installations, only shuttered socket-outlets should be used (see Regulation 553.1.201), industrial socket-outlets including plugs, connectors and appliance inlets complying with BS EN 60309-2 may be used in locations outside of the dwelling where appropriate. Socket-outlets should not be installed in a position where they may be damaged by a lawn mower, hedge trimmer or other garden tools. Equipment may need to be so placed that they are not directly exposed to the effects of the weather, or be placed within an appropriately weatherproof enclosure. Fig 2 shows a SRCD in such an enclosure.

Ponds

Only special equipment and submersible cables designed for use in ponds should be used. Risk of damage to equipment and cables will be minimised by careful positioning and routing of cables. Cables may need additional protection against accidental damage and attack by rodents. All equipment located close to a pond should be protected against ingress of water and resistant to corrosion. Pond pumps should comply with BS EN 60335-2-41. Pond lighting should comply with BS EN 60598-2-16. Other equipment for ponds should comply with BS EN 60335-2-55. Electrical installations associated with large ponds, which could be used for bathing, should comply with the additional requirements for swimming pools. Section 702 of BS 7671 refers. For more detail on installing electrical equipment outside of the dwelling, please visit www.elecsa.co.uk

What is a hybrid home?
What is a hybrid home?

A hybrid home is designed and built from a pleasing combination various materials--for example, reclaimed wood, natural stone or exotic hardwoods....

Read More »
How much does it cost to run a new electrical line?
How much does it cost to run a new electrical line?

Electrical Wiring Cost by Square Foot You'll pay between $3 and $5 per square foot to install new wiring. This price includes all materials and...

Read More »
How much does it cost to pour a 24x24 concrete slab?
How much does it cost to pour a 24x24 concrete slab?

Concrete Slab For Garage Cost A typical 24x24 garage slab costs between $3,057 and $5,944 with prices ranging from $5.31 to $8.31 per square foot...

Read More »
What hurts property value?
What hurts property value?

Some of these factors are out of your control, such as market conditions, interest rates, and the economy, while others are very much in your...

Read More »