DIY Builds
Photo by Ryutaro Tsukata Pexels Logo Photo: Ryutaro Tsukata

How deep bury electric shed?

6-inches Deep Burial Depth If you use galvanized EMT (metal electrical conduit) with individual conductors inside, you can bury it just 6-inches deep. The idea here is that the EMT can withstand a shovel or other significant potential cause of shorting the wiring.

How do you keep mold and mildew out of a shed?
How do you keep mold and mildew out of a shed?

Humidity level control Install a hygrometer to monitor the relative humidity levels. Run a dehumidifier to keep the humidity at optimum levels,...

Read More »
Why should a lift truck not be turned on a ramp?
Why should a lift truck not be turned on a ramp?

Accidents can happen if you make sudden on-the-go directional changes or attempt to turn a forklift on a grade or ramp. This can happen whether the...

Read More »
Are shed plans easy to follow?
Are shed plans easy to follow?

These are! They guide you every step of the way to complete your dream shed.

Learn More »

It’s not uncommon to want to run 120V electrical wiring underground. You may want to send power to your shed, workshop, or garage. Another common use is running power to a lamp post or an electric gate motor. In either case, you should be aware of a few underground wiring requirements in order to meet most current building codes. We show you how to install underground electrical wiring from one location to another.

How to Install Underground Electrical Wiring – How Deep Do I Bury the Wire?

The first question we always get asked is “How deep do we bury the wiring or cable?” That’s a great question. And the answer is that it depends on what wire you use and whether you run it within a conduit or not. Since most people ask the question so that they can meet a particular desire for maximum burial depth, let’s start there. Breaking it down by how deep you bury the underground electrical wiring when you install it, we have the following options:

24-inches Deep Burial Depth

Use direct-burial underground feeder cable at 24-inches deep (or more). You don’t need to use conduit at this depth with UF cable, however, you do need to provide PVC conduit on your vertical feeds starting at 18-inches.

18-inches Deep Burial Depth

You can run THWN-2 conductors inside of PVC conduit at just 18-inches deep in the ground. This protects the wire from damage in the event someone digs overtop of the cable. THWN-2 is basically water-resistant THHN (Thermoplastic High Heat-resistant Nylon-coated wire)

12-inches Deep Burial Depth

At 12-inches deep, you can run direct-burial feeder cable wire that is GFCI-protected. Protect it with PVC where it pops up at the house, garage, or shop.

6-inches Deep Burial Depth

If you use galvanized EMT (metal electrical conduit) with individual conductors inside, you can bury it just 6-inches deep. The idea here is that the EMT can withstand a shovel or other significant potential cause of shorting the wiring.

How to Install Underground Electrical Wiring: General Notes on Burying Wire

If you ever want to use rigid metal conduit or even EMT in place of PVC, you can. Typically, we use gray 3/4-inch PVC for a single line. In addition, while the required burial depths listed above should be generally accurate—check local building codes first. You want to be absolutely certain you’re in compliance before you get started. We typically prefer using PVC conduit when running power to a remote location underground. That gives you a lot more protection over direct burial cable in the long run.

What are lifetime sheds made of?
What are lifetime sheds made of?

(Lifetime sheds are made of high-density polyethylene.) Resin sheds are the newest type of sheds on the market and are quickly becoming the most...

Read More »
What is the most common pitch for a shed roof?
What is the most common pitch for a shed roof?

Traditional roofing materials such as traditional clay tiles and timber shakes/shingles need a relatively steep pitch in excess of 40 degrees to be...

Read More »
These are the Best Shed Plans!
These are the Best Shed Plans!

Comprehensive and Intuitive to follow. Build That Shed!

Learn More »

In the end, just understand your options and take the safest or simplest route depending on your situation. If you can get away without conduit and the wiring is in an area that isn’t liable to get in the way of future digging, then direct-burial cable might be best. If you’re running through the middle of your yard, a PVC or metal conduit might seem the better choice—even if it’s overkill.

How to Install Underground Electrical Wiring Step By Step

We don’t provide a ton of steps to installing underground electrical wiring. Installing the wiring or conduit takes a lot of work—but not a lot of detailed instructions.

Call Before You Dig!

Don’t forget to plan ahead and call before you dig. You don’t want to hit any buried water lines, electrical lines, sewage drains, or anything else. In most municipalities, they will check your property within a day or two for free and when you call. Marking out critical lines with flags before you start really saves you a lot of hassle and headaches. Don’t skip this step!

Digging the Trench

We’ve dug a lot of trenches using shovels. Don’t do it if you value your time. If you have someone you desperately want to torture, or you’re only going several feet, then using a trenching shovel works just fine. If, however, you need to go a good amount of distance with your buried electrical cable, we recommend renting a trencher. You can rent a 24-inch trencher in most places for less than $200 a day. You can even pay less if you only need it for a few hours. It saves you countless hours and hassle, so if you can afford it, grab one at your local tool rental store. Using the trencher, plan your course and dig the trench where you plan to run your direct-burial cable or PVC pipe.

Does a driveway add value?
Does a driveway add value?

Asphalt, concrete, and block paving driveways are the ones that can increase the value of your home the most. It's simply because these are the...

Read More »
Should I wait until spring 2022 to buy a house?
Should I wait until spring 2022 to buy a house?

The mortgage interest rate is declining, housing prices are stable, and buyers have leverage over sellers. Fannie Mae released a nationwide housing...

Read More »
Are shed plans easy to follow?
Are shed plans easy to follow?

These are! They guide you every step of the way to complete your dream shed.

Learn More »

Cut Your Ingress or Egress Holes

Cut your egress and ingress holes from the starting point (for example, your electrical panel) to the end of your run. It helps to use what’s known as a PVC conduit outlet body (LB). These make it easy to feed wire into a building (either the source or the destination garage or shop). You just remove the plate using the two screws and feed the wire as needed without having to worry about making a sharp right-angle turn at the point of entry. Pro Tip: Use a heat gun to bend PVC conduit if you need to make a bend to get up against the house, garage, or workshop with your pipe.

Feeding Your Wire

Many times you can simply push your cable through minimal runs of PVC conduit. If needed, you can use a metal fish tape or even vacuum a pull line through the pipe and use that to pull the wires through a long run.

Finish Off Your Connections and Conduit Fittings

After pulling your wire, make your connections to the electrical panel and finish your conduit fittings. That includes securing the plates on your PVC conduit outlet bodies. Test your run, and pat yourself on the back for a job well done!

Final Thoughts

Nothing beats getting much-needed power to a shed or garage. Attack this type of project with gusto and reap the benefits. As always, consult or use a licensed electrician if things seem to be beyond your level of expertise.

What can I use instead of a screen porch?
What can I use instead of a screen porch?

If you don't want something permanent like a screen, try some stylish outdoor curtains. Not only will they help with the bugs but also filter the...

Read More »
Does PEX need to be sleeved in concrete?
Does PEX need to be sleeved in concrete?

A pipe sleeve is a pipe of larger size that protects a smaller pipe inserted in the inside. In addition to protection, the sleeve pipe allows...

Read More »
Is rebar needed in concrete slab?
Is rebar needed in concrete slab?

Rebar is not necessary for every concrete project. The general rule of thumb is that if you are pouring concrete that is more than 5 inches in...

Read More »
Can I build my own shed?
Can I build my own shed?

Yes, with the right plans you can build your dream shed.

Learn More »
Can you burn MDF on an open fire?
Can you burn MDF on an open fire?

Also beware of burning, chipboard or MDF. These have been made using resin which produces toxic gasses when burnt, which are harmful to the...