How deep should electric lines be buried?

36 inches Direct buried cables or cables in flexible nonmetallic enclosures shall be installed at a depth of at least 36 inches.

How much should be the clear space for horse in the shed?
How much should be the clear space for horse in the shed?

Roofs should be high enough to provide adequate ventilation including good air circulation. There should be a reasonable clear space 0.6 to 1.0 m...

Read More »
How much weight can particleboard hold?
How much weight can particleboard hold?

A typical particle board desk product can carry about 32lbs with relative ease. In some instances, that can go up to about 45lbs, depending on the...

Read More »

This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov . These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at https://www.dir.ca.gov/od_pub/disclaimer.html

Subchapter 5. Electrical Safety Orders

Group 2. High-Voltage Electrical Safety Orders

Article 19. Outdoor Wiring (Formerly Article 68)

§2830. Insulated Conductors.

(a) General. Insulated cables shall be of a type suitable for the voltage and service conditions. All cables installed underground shall have a grounded metallic sheath, shield, or a bare concentric grounded conductor, or shall be installed in grounded metallic conduit.

(Title 24, Part 3, Section 3-710-88(a).)

(b) Cable Installed in Buildings. Where installed in buildings, cables energized above 35,000 volts shall be encased in at least 3 inches of concrete or equivalent fire-resistant material.

(Title 24, Part 3, Section 3-710-88(c).)

(c) Direct Buried Cables. Direct buried cables or cables in flexible nonmetallic enclosures shall be installed at a depth of at least 36 inches. Lesser depths shall be permitted to be employed if the cable is armored with a minimum of No. 12 BWG steel wire closely wound or two layers of steel tape each at least 0.020 inch thick, or if the cable is protected by a layer of concrete at least 3 inches thick above the cable. EXCEPTION: Lesser depths than those listed are permitted where cables rise for terminations and splices or where access is otherwise required.

(Title 24, Part 3, Section 3-710-88(c).)

(d) Identification. Cables shall be labeled at all circuit terminals, sectionalizing points, vaults, rooms, etc. The labels shall, as a minimum, show phase and circuit designation and nearest sectionalizing points.

(1) Changes in labeling shall be made concurrently with changes in circuit.

(Title 24, Part 3, Section 3-710-88(d).)

(e) Neutral Conductor. The size and insulation of neutral conductors shall be in accordance with Section 2818.

(Title 24, Part 3, Section 3-710-88(e).)

(f) Shielding. All cables normally operated above 5,000 volts shall have insulation shielding, except that shielding shall not be required for series street lighting circuits operating at less than 7,500 volts. Metallic shielding at terminations shall be effectively grounded. If shielding is sectionalized, each section shall be effectively grounded.

(Title 24, Part 3, Section 3-310-61.)

(g) Terminations. Cable terminations shall be suitable for the voltage and service conditions.

(Title 24, Part 3, Section 3-710-3(c).)

NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code; and Section 18943(c), Health and Safety Code.

HISTORY

1. Editorial correction filed 11-2-83 (Register 83, No. 45).

2. Editorial correction of subsection (e) filed 11-3-83 (Register 83, No. 45).

3. Amendment filed 12-10-87; operative 1-9-88 (Register 88, No. 1).

Go Back to Article 19 Table of Contents

What is the best material to put under a shed?
What is the best material to put under a shed?

Gravel is the best shed foundation, especially for portable buildings that come with a wood floor. Concrete is the ideal foundation for a garage or...

Read More »
How high can a shed be in back garden?
How high can a shed be in back garden?

If it will be within 2m of the boundary of the house, it must be 2.5m high. its eaves will be more than 2.5m high. it will include a veranda,...

Read More »

What time do burglars break in at night?
What time do burglars break in at night?

Thieves Tend to Break In Between 10 AM and 3 PM Everything You Should Know, Hollywood simply has it wrong. There will always be exceptions. Some...

Read More »
How do you anchor a metal shed to the ground?
How do you anchor a metal shed to the ground?

How to Properly Anchor a Shed: The Only Guide You Need Drill or dig the holes, tamp some gravel into the bottom. Slide a sonotube in to form it up....

Read More »
Does a shed add property value?
Does a shed add property value?

A shed can even help to increase your asking price when you decide it's time to sell. In fact, some professionals estimate that a new shed could...

Read More »
Can I build my own shed?
Can I build my own shed?

Yes, with the right plans you can build your dream shed.

Learn More »
How long can a garage be without planning permission?
How long can a garage be without planning permission?

You can build a garage or outbuilding on your property without planning permission as long as it's of a reasonable size – no higher than 4 metres....

Read More »