DIY Builds
Photo by Maria Orlova Pexels Logo Photo: Maria Orlova

How far above the roof should a B Vent be?

2 feet All metal vents must terminate at least 2 feet above the roof surface and anything within 10 feet of the vent, such as the crest of a roof ridge; missing components, such as a chimney cap; firestops not installed at either the top or bottom side of the joist where the vent passes through floors or the roof.

How are garden sheds secured to the ground?
How are garden sheds secured to the ground?

Two common anchor types include: Auger Style Anchors: Auger anchors resemble large corkscrews and this type of anchor screws directly into the...

Read More »
Does cutting down trees decrease property value?
Does cutting down trees decrease property value?

Can cutting down a tree increase property value? Removing dying or hazardous trees can increase property value, experts say. “This mostly depends...

Read More »
Are shed plans easy to follow?
Are shed plans easy to follow?

These are! They guide you every step of the way to complete your dream shed.

Learn More »

by Nick Gromicko, CMI®

Type B Vents

Type B vents are vents suitable only for listed, draft-hood equipped, gas-fired appliances, including most domestic heating and hot water systems.

They may not be used with any of the following appliances:

wood-burning appliances, such as fireplaces and wood-burning stoves;

incinerators;

oil-fired equipment;

coal-fired equipment;

any appliance that burns anything other than liquid propane or natural gas; or

any appliance that produces flue gasses that exceed 480° F (249° C).

Type B vents must be equipped with their own special chimney caps. If the cap is damaged or lost, it should not be substituted with something not recommended by the manufacturer. The clearance required from combustible materials is printed on the flue’s exterior metal surface, and is generally 1 or 2 inches.

Type L Vents

Type L vents are designed for venting approved oil-fired and natural-gas appliances that produce draft hood flue gasses that do not exceed a temperature of 570º F (299º C), or 926º F (299º C) for 10 minutes in an over-fire situation. The minimum clearance from combustible materials is generally 3 inches. Type L vents should not be used to vent coal- or wood-fired appliances. It may be difficult to tell the difference between Type L and Type B vents because they are made from similar components, but the vent type should be clearly printed on the vent. Both are double-walled, although Type L vents generally have a stainless steel inner wall, while Type B vents do not. Regardless of the vent type, InterNACHI inspectors may check for the following defects: deterioration of the outer wall, which is likely caused by failure of the inner metal lining; violation of roof clearance requirements. All metal vents must terminate at least 2 feet above the roof surface and anything within 10 feet of the vent, such as the crest of a roof ridge;

missing components, such as a chimney cap;

firestops not installed at either the top or bottom side of the joist where the vent passes through floors or the roof. The firestop should allow a fire-resistance rating equal to or greater than the floor or roof assemblies through which the vent passes;

blocked bird screens, often caused by freezing moisture in cooler climates;

crucial joists, rafters or other load-bearing structural members that have been cut to allow for the vent to pass. Plumbing and electrical lines should also not be disturbed by the vent; and whether the vent is too high or too low. Manufacturers may set minimum and maximum height requirements for the whole vent assembly, such as the AirJet Type L vent, whose minimum height is 6 feet and maximum height is 30 feet. Inspectors may recommend that extra corrosion resistance for vents be provided by a stainless steel cap, stainless steel jacketed pipe sections, or stainless steel or aluminum flashings and storm collars. They may also recommend that clients use commercially available combustion-enhancing, acid-neutralizing fuel additives to prevent damage caused to vents from sulfuric acid. In summary, Type B and Type L vents are designed to vent gasses from specific types of appliances and under certain conditions.

Can I put my Keter shed on gravel?
Can I put my Keter shed on gravel?

Can you put a wooden shed directly onto grass, dirt or gravel? No. Wooden sheds are susceptible to water damage. So it's vital you keep them off...

Read More »
What is the difference between Quikrete and Sakrete?
What is the difference between Quikrete and Sakrete?

Sakrete tends to have big pebbles in their mix, even though their composition is similar. So, you might have to put enough cement down to cover the...

Read More »
Can I build my own shed?
Can I build my own shed?

Yes, with the right plans you can build your dream shed.

Learn More »

Are metal vents better than plastic?

Along with being virtually unaffected by the impact of a baseball, there are a number of reasons for choosing plastic vents over metal vents. “Metal vents — can be susceptible to bent flanges and denting from shipping and handling. Plastic vents are a lot lighter and much more durable."

Using plastic is important, but it’s also important to choose the right type of plastic. With a Duraflo® roof vent made from polypropylene (PP), you’re getting a product that won’t crack in temperatures up to -40 degrees Celsius. Alternatively, polyethylene (PE) resins won’t last in colder climates and will often crack. At Duraflo®, we also include UV protective additives in our proprietary material formulation in our roof vents to ensure our products will not be damaged by the elements. You can read more about the different types of roof vents, and what works best for your application in our blog here: Choosing the Right Roof Vent.

How much should I charge to build a 10X12 shed?
How much should I charge to build a 10X12 shed?

How much does it cost to build a 10×12 shed? To calculate the cost to build a 10×12 shed, we added up the materials cost for a shed based on these...

Read More »
Does firewood need to be in the sun?
Does firewood need to be in the sun?

The best place to season your firewood is outside in the sunlight. Firewood that is placed indoors will not season properly and there is always the...

Read More »
Can I build my own shed?
Can I build my own shed?

Yes, with the right plans you can build your dream shed.

Learn More »
Can a metal shed sit on grass?
Can a metal shed sit on grass?

No. Many metal sheds don't come with floors, so that would obviously be a disaster! However, metal sheds are also heavy, so even when they have...

Read More »
Are shed plans easy to follow?
Are shed plans easy to follow?

These are! They guide you every step of the way to complete your dream shed.

Learn More »
Why is perspective drawing so hard?
Why is perspective drawing so hard?

Sometimes the biggest problem with perspective is the word 'perspective'. It is too off-putting and brings up memories of vanishing points and...

Read More »