How far can you run duct work?

The lengths of straight sections of duct add up to 36 feet for the supply side and 13 feet for the return side. The fittings add up to 290 feet and 85 feet respectively. This is typical. Fittings dominate when it comes to using up the available static pressure, so you have to choose them carefully.

Why are plastic sheds so cheap?
Why are plastic sheds so cheap?

The big selling point of a plastic shed is that it won't rust or rot. Inexpensive. The plastic materials used allow these sheds to be sold at a...

Read More »
What is the most magical flower?
What is the most magical flower?

Flowers That Symbolise Magic and Power Lilac. Lilacs are pretty flowers that bloom during the late spring and early summer. ... Lavender. Lavenders...

Read More »

Today we move another step down the road of duct design. I started the series with a look at the basic physics of air moving through ducts. The short version is that friction and turbulence in ducts results in pressure drops. Then in part 2 I covered available static pressure. The blower gives us a pressure rise. The duct system is a series of pressure drops. We can divide the pressure drops into two categories: those resulting from the ducts and fittings and those resulting from all of the components that aren’t ducts and fittings (e.g., registers, grilles, filters…). When we subtract the non-duct/fitting pressure drops from the rated pressure rise (total external static pressure) of the blower, we get the available static pressure. That’s the total pressure drop we have available for the ducts and fittings and is what sets our duct pressure budget. What we want to get out of this in the end is the proper duct and fitting sizes. We have a certain amount of available static pressure to use up. If our ducts are too small, we can end up with either too little air flow in the case of a fixed-speed blower (PSC, which stands for permanent split capacitor), or we get the air flow but use too much energy with a variable-speed blower (ECM, which stands for electronically-commutated motor). The first step in finding the proper duct and fitting sizes is to find the total effective length (often called equivalent length), the topic of today’s article.

What is effective length?

Length is length, right? Why do we need something else called effective length? The answer lies in fittings, those duct components that allow you to take air out of a trunkline, split a single duct into two runs, turn the air, and more. For straight duct sections, the effective length is the same as the length. Well, that’s the idea anyway. If we use flex duct and don’t pull it tight, the pressure drop will be greater than if it were pulled tight. Texas A&M did a study on the effect of flex duct not pulled tight and the results are astounding. In my article on this research, I showed from their results that a 6″ duct moving 110 cfm when pulled tight will move only about 70 cfm with 4% linear (longitudinal) compression and about 40 cfm or less at 15% compression. (I’ll write more about the effect of different duct types in the HVAC design process later in this series.) For our purposes here, I’m going to assume that the ducts we’re using are either rigid metal or flex pulled tight. ASHRAE now has a duct calculator with options for 4%, 15%, and 30% longitudinal compression, but that’s not for use in designing duct systems. It’s to show how bad existing systems are if the flex isn’t pulled tight or to scare installers into pulling it tight. So, we’ve got straight sections of duct with their effective length being equal to the actual length. And then we’ve got fittings. Each fitting — whether it’s splitting the air flow, reducing the duct size, or turning the air — will cause a pressure drop. In the duct design process, however, it’s more convenient to categorize these pressure drops by the length of straight duct run that would create the same pressure drop. And that, my friend, is the definition of effective length.

What makes a woman captivating?
What makes a woman captivating?

Captivating women know their worth and aren't afraid to show it. They walk with purpose, have a strong presence, and aren't afraid to be...

Read More »
What can I use instead of drywall in a shed?
What can I use instead of drywall in a shed?

Skip the Walls. Drywall. Bead Board/Paneling. Upcycled Pallets. Fabric/Dropcloths. Plywood. Pegboard. Tin/Metal Roofing. More items... • May 7, 2021

Read More »
These are the Best Shed Plans!
These are the Best Shed Plans!

Comprehensive and Intuitive to follow. Build That Shed!

Learn More »

Before sizing a duct system, we have to lay out all the ducts. Here’s an example of one we did recently. It shows the duct layout with all vents, fittings, air flows, and duct sizes. To find those duct sizes, the software we use (RightSuite Universal) calculates the effective length of the most restrictive run. From the return grille to the supply register in that run, it adds the lengths of the straight runs and the effective lengths of all the fittings. Each fitting we choose has an effect on the pressure drop and total effective length (TEL). We can look them up in tables, like the one below showing effective lengths for various elbows. The main variables we have to work with for this fitting type are:

Radius of the turn (R)

Diameter of the duct (D)

Number of pieces

Round or oval

When we choose fittings, we pick them based on what’s commonly available at HVAC supply houses. We also go a little conservative here because we’re doing third party HVAC design and don’t have control over the installation. For example, most of the elbows used in actual duct systems have 4 or 5 pieces. We often choose a 3 piece elbow in our design, though, because it gives us a little slack in the design. If the installer uses the 4 or 5 piece elbow instead, with 5 feet less effective length, the actual duct system will be less restrictive than the designed duct system, at least in that part. The total effective length (TEL) is the sum of all those fitting effective lengths plus the lengths of straight duct. If you’re doing it by hand, you have to go through the process for every single duct run. Then you choose the one that has the greatest total effective length. You do NOT use the sum of all the ducts and fittings. Here’s a screenshot from RightSuite Universal showing the total effective length in one of our designs. The lengths of straight sections of duct add up to 36 feet for the supply side and 13 feet for the return side. The fittings add up to 290 feet and 85 feet respectively. This is typical. Fittings dominate when it comes to using up the available static pressure, so you have to choose them carefully. Just take a look at that table of elbows above. If you choose well, you can be at 10 or 20 feet of effective length. If you choose that smooth mitered elbow, however, you end up with 75 feet.

The next step

What temperature is too cold for tent camping?
What temperature is too cold for tent camping?

30 to 40 degrees Fahrenheit How cold is too cold for camping in a tent? 30 to 40 degrees Fahrenheit (-1 to -4 degrees Celsius) is generally...

Read More »
What materials are needed for a 12x12 shed?
What materials are needed for a 12x12 shed?

A List of Materials Needed to Build a 12x12 Wood Shed Wood. Wood will be your biggest expense when constructing your 12-by-12 shed. ... Plywood....

Read More »
Are shed plans easy to follow?
Are shed plans easy to follow?

These are! They guide you every step of the way to complete your dream shed.

Learn More »

Once you lay out your ducts and choose your fittings, you have a total effective length. But here’s a caveat: Those effective lengths for fittings depend on the velocity of the air, too, and it’s not a linear relationship. David Butler mentioned this in his comment below, and it deserves its own article in this series. To summarize where we’re at now, let’s add the steps from today’s article:

The blower creates a pressure rise to move air through the ducts.

It’s rated for a certain amount of air flow at a specific total external static pressure.

The ducts, fittings, and other components cause pressure drops.

Subtracting the pressure drops for all the things that aren’t ducts or fittings from the total external static pressure yields the available static pressure. The available static pressure is the pressure drop budget you have to work with when designing the ducts. Each fitting has an effective length that equates its pressure drop to an equivalent amount of straight duct. When you add up the effective lengths of all the fittings and then add that number to the length of the straight sections in the most restrictive runs in the return and supply ducts, you find the total effective length (TEL). The next step is to take your available static pressure and figure out what friction rate you have to work with in sizing the ducts. That’s next in this series.

Buy the ACCA Manuals on Amazon*

Other articles in the Duct Design series:

The Basic Principles of Duct Design, Part 1

Duct Design 2 — Available Static Pressure

Duct Design 4 — Calculating Friction Rate

Duct Design 5 — Sizing the Ducts

Related Articles

The 2 Primary Causes of Reduced Air Flow in Ducts

Don’t Kill Your Air Flow with This Flex Duct Disease

The Science of Sag – Flex Duct and Air Flow

The Secret to Moving Air Efficiently through Your Duct System

* These are Amazon Associate links. You pay the same price you would pay normally, but Energy Vanguard makes a small commission if you buy after using the link.

NOTE: Comments are moderated. Your comment will not appear below until approved.

Should all vents be open in winter?
Should all vents be open in winter?

When vents are closed, that pressure builds up, potentially causing damage to the HVAC system. Increased air pressure can create cracks and holes...

Read More »
What is the difference between PVC and uPVC?
What is the difference between PVC and uPVC?

' The difference between the two is that PVC contains plasticizer additives whereas uPVC doesn't. The addition of plasticizers has an important...

Read More »
How many plumbing vents should a house have?
How many plumbing vents should a house have?

At least one main vent stack is required for every building that has plumbing when connecting separately to the sewer for the building or its...

Read More »
How many Boxabl homes have been built?
How many Boxabl homes have been built?

Boxabl has produced about 200 homes so far, 156 of which have gone to the Department of Defense for military housing. Jun 29, 2022

Read More »