How far down does electrical conduit need to be buried?

In general, bury metal conduits at least 6 inches below the soil surface. You may also run them at a depth of 4 inches under a 4-inch concrete slab. Under your driveway, the conduits must be below a depth of 18 inches, and under a public road or alleyway, they must be buried below 24 inches.

Does a garage increase home value?
Does a garage increase home value?

Don't View a Garage as an Expense There are plenty of stories about homeowners who invested a few thousand dollars in a new garage, only to find...

Read More »
How much space do I need around a shed?
How much space do I need around a shed?

But generally, you need to maintain at least 5 feet between the further edge of your shed and the fence. We also recommend double-checking your...

Read More »
Are shed plans easy to follow?
Are shed plans easy to follow?

These are! They guide you every step of the way to complete your dream shed.

Learn More »

When you run buried electrical cable -- for example from a house to a garage or to a gazebo -- it has to be protected to prevent mechanical damage to the insulation. The National Electrical Code gives minimum burial depth recommendations and building codes specify local requirements that you must follow. Check with your local inspector for special regulations, and get a permit if necessary before carrying out any work.

Video of the Day

Burial Depth for Metal Conduits

Running underground cables in metal conduits approved for buried cables is the most expensive method, but also the one requiring the least digging. In general, bury metal conduits at least 6 inches below the soil surface. You may also run them at a depth of 4 inches under a 4-inch concrete slab. Under your driveway, the conduits must be below a depth of 18 inches, and under a public road or alleyway, they must be buried below 24 inches. In solid rock, sink them into the rock so the upper edges are 2 inches below the rock surface, and cover them with concrete.

Requirements for Nonmetallic Conduits

Nonmetallic conduits, or raceways, approved for buried cable give less protection than metal conduits and require greater burial depths. In general, bury the nonmetallic conduits 18 inches below grade, or 12 inches if protected by 2 inches of concrete or equivalent. For all other applications, the burial depth for nonmetallic conduits is the same as specified for metal conduits.

Direct Burial of Cables or Conductors

Underground feeder cables, labeled UF, can be buried without additional protection from conduits because they have a tough jacket designed for burial. Bury UF cables 24 inches below the soil surface, and 18 inches deep when protected by 2 inches of concrete. For all other applications, the burial depth is the same as specified for conduits, except that conduits are required for UF cables in 2 inches of solid rock.

Special Measures for Low-Power Cables

If your cables are operating a 120-volt circuit, protected by a circuit breaker rated at 20 amps or less, and have a ground fault circuit interrupter to protect the underground segment of the cable, you may reduce the burial depth of your cables. The generally applicable depth is 12 inches, or you can reduce it to 6 inches if you protect the cables with 2 inches of concrete. Under a driveway, you may only need 12 inches of burial depth. Conduits are required for installation in 2 inches of solid rock with concrete. These depth reductions apply no matter which burial method is chosen.

Reduced Depths for Control Cables

Control circuits carrying less than 30 volts are inherently less dangerous than those carrying higher voltages and can therefore be buried less deeply. The usual required depth is 6 inches. For all other applications, the same depths as those for buried UF cable apply, except that the control cables have to be buried 18 inches deep under driveways.

How do you make a shed livable?
How do you make a shed livable?

Top Ways To Turn A Shed Into A living Space Run power to the shed for lights, electronics & HVAC. Choose a way to climate control – Heating &...

Read More »
Can Neighbour grow ivy on my fence?
Can Neighbour grow ivy on my fence?

ANSWER: The ivy will belong to the neighbour as its roots appear to come from the neighbouring property. If the end-terrace wall is structurally...

Read More »
Can I build my own shed?
Can I build my own shed?

Yes, with the right plans you can build your dream shed.

Learn More »

Will clothes go Mouldy in a shed?
Will clothes go Mouldy in a shed?

If they are kept in your shed, humidity and high temperatures could cause them to stick together or even grow mould. If kept in your shed, insects...

Read More »
What is the standard slope for a wheelchair ramp?
What is the standard slope for a wheelchair ramp?

Maximum slope for hand-propelled wheelchair ramps should be 1" of rise to every 12" of length (4.8 degree angle; 8.3% grade). Maximum slope for...

Read More »
Are shed plans easy to follow?
Are shed plans easy to follow?

These are! They guide you every step of the way to complete your dream shed.

Learn More »
Do you need to change compost in pots every year?
Do you need to change compost in pots every year?

When it is no longer convenient to repot them every year into a bigger pot, they should be repotted in the same pot at least every other year....

Read More »
Can I build my own shed?
Can I build my own shed?

Yes, with the right plans you can build your dream shed.

Learn More »
How common are roof leaks with solar panels?
How common are roof leaks with solar panels?

Roof leaks after solar panels are extremely rare. When roof leaking after the solar panels are fitted does occur, however, it usually becomes...

Read More »