DIY Builds
Photo by Felicity Tai Pexels Logo Photo: Felicity Tai

How many receptacles can be on a 15 amp circuit?

8 outlets Technically, you can have as many outlets on a 15 amp circuit breaker as you want. However, a good rule of thumb is 1 outlet per 1.5 amps, up to 80% of the capacity of the circuit breaker. Therefore, we would suggest a maximum of 8 outlets for a 15 amp circuit.

What's the cheapest roof to put on a shed?
What's the cheapest roof to put on a shed?

Roofing With MSR Roll Materials In most cases, MSR roll roofing is the cheapest shed roof material you can buy. Roll roofing is also the easiest...

Read More »
How do I print full page without white border?
How do I print full page without white border?

Printing without Margins to Match Paper Size In the printer driver, open the settings screen. Select the paper source. From the Paper Source list...

Read More »
Can I build my own shed?
Can I build my own shed?

Yes, with the right plans you can build your dream shed.

Learn More »

Technically, you can have as many outlets on a 15 amp circuit breaker as you want. However, a good rule of thumb is 1 outlet per 1.5 amps, up to 80% of the capacity of the circuit breaker. Therefore, we would suggest a maximum of 8 outlets for a 15 amp circuit.

National Electrical Code & Outlets

The National Electrical Code (NEC) does not limit the number of outlets per circuit. The NEC only states that a circuit cannot supply more than 80% of the circuit breakers limits. This is so the circuit breaker does not constantly trip during regular use. So, if you have a 15 amp circuit with 20 outlets, you should be fine as long as you are not running more than 12 amps through the circuit at one time. While this would be an extreme case, read further to find out how many amps you may use on a circuit.

How Many Amps Will I Use?

To find out how many amps you need or how many you will use, use this formula: 80%*(Amps) = Watts/Volts. Also, you should know modern-day U.S. outlets run on 120 volts (unless it is a special appliance connection like a dryer). So, if you are using a 15 amp circuit and you are using regular 120-volt outlets, then the max watts you can use is 1440 watts. This ensuring your circuit does not supply more than 80% of the total 15 amp circuit. All electrical appliances like TVs, chargers, and lightbulbs should state their wattage on the packaging so you can just add up the expected wattage from each appliance to get your total wattage for the circuit.

How Many Outlets Are In Most Bedrooms

Most new construction bedrooms have an outlet every 6 feet, or on every wall. They would also have a junction box on the ceiling for a light and fan. For example, a master bedroom could have 7 outlets, and then a light fixture at the ceiling for a fan. All while, being on a 15 amp circuit.

Final Thoughts

While there is no direct rule for how many outlets you can have on a 15 amp circuit, you should not have more than 1440 watts of power plugged into those outlets at one time. Again, a good rule of thumb is 1.5 amps per outlet, but stop at 80% of the total circuit breaker amperage so the breaker does not trip constantly. In the case of 15 amps, we recommend a maximum of 8 outlets. During our home inspections, while we do not count the specific number of outlets in any given room, we will ensure the amperage per room is appropriate. For example, a kitchen should have more than a 15amp breaker.

If you have further questions, be sure to comment below!

Learn about preventing power surges or how many outlets can you put on a 20 amp circuit.

How can I get rich fast for free?
How can I get rich fast for free?

How to Make Money Online for Free: 11 Best Ways in 2022 Become a virtual assistant. Do research online. Transcribe audio and video files. Set up a...

Read More »
Can you insulate a metal shed?
Can you insulate a metal shed?

Closed-cell spray foam is the best option for insulating your metal shed. It offers excellent R-value per inch, as it can achieve R-18 with little...

Read More »

Can PEX be used for electrical conduit?

Pex tubing or any other plumbing pipe is not listed for use as an electrical raceway. If you just want some physical protection for the Cat 5 cable then PVC electrical conduit will perform nicely. Save your scrap pex for a plumbing project.

Because this is an indoor run, I'm not entirely sure why conduit would be helpful, except in eventually pulling more cables, as you mention. That said, I pulled CAT6 through 3/4" PEX, and that was difficult. If you have 1/2", you're not likely going to be able to pull it through at all if it's terminated, and you probably can't get any more cables in there afterward.

Overall, I don't see a point to it.

If you wanted to do it, you could. You could probably use a PG fitting to connect it to boxes on either end. Keep pull tape in the PEX so you can pull more easily in the future. It helps to have twice the length of the run so you can hold it on either end, attach your cable, and pull without losing the pull tape on either end.

Will mice come near me while I sleep?
Will mice come near me while I sleep?

So is there a chance that a mouse will crawl on you while sleeping? If mice have already taken refuge in the bedroom, there's a chance that they...

Read More »
What do you use to insulate a shed?
What do you use to insulate a shed?

To insulate a shed via its walls, there's a choice of materials, including bubble wrap, foam boards and fiberglass. Use bubble wrap in a shed made...

Read More »
Can I build my own shed?
Can I build my own shed?

Yes, with the right plans you can build your dream shed.

Learn More »
Is concrete with fiberglass vs rebar?
Is concrete with fiberglass vs rebar?

Rebar is pretty different to traditional wire mesh, and it is very different to concrete fibermesh. That is because rebar comes in individual rods...

Read More »
Can I build my own shed?
Can I build my own shed?

Yes, with the right plans you can build your dream shed.

Learn More »
Can you put metal roofing on a 1/12 pitch?
Can you put metal roofing on a 1/12 pitch?

Can You Put A Metal Roof On A Low Slope? Just about any type of metal roofing panel will work with a 3:12 roof pitch or greater. However, when the...

Read More »