DIY Builds
Photo: Anna Nekrashevich
That means the joists can support a minimum of 40 pounds per square foot live load. Though, by consulting the 50 pounds per square foot live load/10 pounds per square foot dead load table, you can see the joists' span would need to be reduced to 11 feet 11 inches to support heavier weight safely.
200 square feet A 10×20 shed is large enough to store anything. Okay, maybe not anything, but you get the gist. 200 square feet gives you the...
Read More »
Pressure washing is something that you should be very wary of when cleaning UPVC and glass. The force exerted by a pressure washer can be...
Read More »
These are! They guide you every step of the way to complete your dream shed.
Learn More »A properly constructed living room floor is designed to support heavy loads, but knowing how much weight your floor will truly hold can be tricky. We've done our research for this guide to help you understand what factors determine your floor's safe weight limits. Using this knowledge, you can make informed choices. You’ll also find some useful tips to quiet those noisy floorboards. Disclosure: We may get commissions for purchases made through links in this post. Most local building codes are based on the International Residential Code or IRC. This code requires non-sleeping rooms such as living rooms to support a minimum live load of 40 pounds per square foot. Live load is the weight of furniture, people, and anything that is not part of the building’s construction, also known as dead load. Multiply your living room’s square footage by 40 pounds per square foot, and you’ll have the minimum safe live load of the space. The average US living room measuring 12x18 or 216 square feet puts the minimum allowable live load of the typical living room at 8,640 pounds. Averages can be deceiving, so below, we’ll go into some aspects to consider when adding heavy furniture, hosting large gatherings, or otherwise testing the limits of your floors. This is important because there are real safety concerns to overloading a living area.
36 inches Direct buried cables or cables in flexible nonmetallic enclosures shall be installed at a depth of at least 36 inches.
Read More »
Ramp Installation Costs Item Unit cost Line Cost Concrete $20-$50 per feet $600-$1,500 Galvanized Steel $33-$40 per feet $990-$1,200 Wood $13-$50...
Read More »Next, use a span table to cross-reference the joists' size, the spacing between them, and their span across the room against their required Fb and E values. Compare the values between tables to find the highest pounds per square foot load allowable for your specifications. For example, consider a floor with 2x8 joists of number 1 grade beech, spaced at 16 inches, and spanning 12 feet 10 inches. The 2021 design value table shows a normal Fb value of 1,450 and an E value of 1,600,000 for that size and beech grade. The 2021 span table for a 40 pounds per square foot live load/10 pounds per square foot dead load shows a required Fb of 1,255 and a minimum E value of 1,600,000. That means the joists can support a minimum of 40 pounds per square foot live load. Though, by consulting the 50 pounds per square foot live load/10 pounds per square foot dead load table, you can see the joists' span would need to be reduced to 11 feet 11 inches to support heavier weight safely. If you can access your floor joists and visually inspect them - say, through your basement - take note of structural quirks which might affect their integrity. Are there wood grain imperfections or large knots in the joists? Have any of them been modified or had sections cut away to fit plumbing? Is there termite damage? Knowing all these aspects of your floor’s construction can help you decide the safest placement of large furniture.
LP Siding – If you love the look of traditional wood siding, but you want better durability, LP siding might be the best option for your shed. It...
Read More »
Although your horse can be safely left alone overnight, you should never leave your horse unattended for longer than 10 hours. Doing so can have a...
Read More »
If your floors squeak year-round, it may be due to less-than-ideal construction practices. If the builders used a nailgun instead of screws when attaching the joists' subfloor, this could lead to noisy floors, as nails won’t stay as secure as screws. Using lower quality building materials in the subfloor, such as particleboard rather than plywood, may cause the floor to wear out more quickly. Methods like these can lead to small, squeaky spaces developing between the subfloor and joists.
Much debate of the significance of the double front doors has produced some general consensus that it represents the adaptation of traditional...
Read More »
Woodworking is indeed profitable if you are skilled, know your worth, and have an idea of where and who you can sell your creations. However, it's...
Read More »
Carports and canopies come under the same umbrella as outbuildings, so dependant upon a few rules you may not need to gain planning permission from...
Read More »
Ants cannot climb up the aluminum surface Due to its smooth surface, the ants will have the chance to place their claws or suction like legs on the...
Read More »