DIY Builds
Photo: Blue Bird
The R-value of foil-faced bubble wrap is so low that it has few, if any, advantages over rigid foam. Of course, the product's foil facing can be used as a radiant barrier — but if you want a radiant barrier, cheaper products are available.
Pros: Hip roofs are one of the strongest designs for a roof. The inward slope on all four sides of a hip roof makes it an excellent design for both...
Read More »
A building purchased from a dealer (in stock on the dealer's lot) will take 7-10 days to deliver. If the building purchased has to be manufactured...
Read More »
Casitas, or guest houses, are accessory dwelling units (ADU) the are separate from the main house. These can be useful in retirement because you...
Read More »
Lay out the building to scale including the door. Measure the items then cut out pieces to represent each one and try to arrange them inside the...
Read More »
These are! They guide you every step of the way to complete your dream shed.
Learn More »Many of the manufacturers and distributors that publish exaggerated R-values deliberately blur the bright legal line that separates product R-values from assembly R-values.According to federal law, the R-value of an insulation product — for example, a piece of 1-inch thick polyisocyanurate — is the R-value of the insulation alone. That's the R-value which insulation manufacturers are required to report on their packaging and in their advertising; the requirement is spelled out in the Federal R-Value Rule, a law that applies to manufacturers, retailers, and builders.The R-value of a building assembly is something different. For example, if you build a wall with a layer of interior polyisocyanurate, followed by horizontal 1x4 strapping and drywall, the air space between the polyiso and the drywall has a measurable R-value. If you want to calculate the R-value of the entire wall assembly, you would need to calculate the R-value of the air space and add that R-value to the R-value of all the other layers. Once you've done that, you'll know your wall assembly R-value.Here's the key point: polyiso manufacturers can't claim the R-value of an air space in their labeling or advertising (unless the advertising makes a very clear distinction between the product R-value and the R-value of a hypothetical building assembly).
Provides Better Security In terms of security, steel sheds are able to provide increased protection against thieves. Unlike some wooden or quality...
Read More »
With that in mind, building a “shedcation” can be a great option if you want to become an Airbnb host. It is a great way to make extra money,...
Read More »
These are not examples of victimless crimes; there are victims. One victim is a blogger who reports using this sub-slab assembly: "In basement, install Insul-Tarp over crushed rock, single layer of wire mesh, and Wirsbro [hydronic] tubing, pour concrete (pump hose will go through stairwell hole)." Unfortunately, Insul-Tarp has an R-value of R-2 or less. For years, however, the manufacturer of Insul-Tarp claimed that the product was rated at R-7 or more. The blogger who specified Insul-Tarp believed the false claims, which is why he wrote, "This is what the Insul-Tarp looks like. The exterior is some kind of tough fabric, then there are two layers of thin white foam, then a layer of bubble wrap. Hard to believe this can be equivalent of 2 inches of styrofoam." Indeed, it is hard to believe — so hard, in fact, that the Federal Trade Commission initiated court action that forced Meyer Enterprises, the manufacturer of Insul-Tarp, to stop making false claims. According to the FTC complaint, Meyer Enterprises "claimed Insul-Tarp's R-value is 7.54, but in reality Insul-Tarp's R-value could not be more than 2." Although the major manufacturers of foil-faced bubble wrap have (almost) cleaned up their act, some still include exaggerations on their websites.One manufacturer that trumpets exaggerated R-values is EcoFoil (a.k.a. rFoil, a.k.a. Covertech Fabricating). The EcoFoil website describes the company's duct wrap as an R-8 product, even though the R-8 claim is based on an assembly that includes an adjacent air space. The company also claims that "EcoFoil [foil-faced bubble wrap] under concrete insulation is superior to traditional, outdated forms of concrete floor insulation such as polystyrene or foam sheets." This statement is false.Elsewhere, EcoFoil claims that its 5/16-inch-thick bubble wrap product, which is called "Under Concrete Insulation," has an R-value of R-3.8. It does not.Another bad apple is Insulation4less, which retails a thin product called Prodex Total. On its website, the company states, "Prodex Total has a nominal thickness of 5 mm (13/64 inch) closed cell polyethylene foam covered on both sides with .0012 (00.03 mm) aluminum foil facing. ...R-value R-16 unaffected by humidity."Prodex may be unaffected by humidity — but it is seriously affected by gross exaggeration.These are not examples of victimless crimes; there are victims. One victim is a blogger who reports using this sub-slab assembly: "In basement, install Insul-Tarp over crushed rock, single layer of wire mesh, and Wirsbro [hydronic] tubing, pour concrete (pump hose will go through stairwell hole)."Unfortunately, Insul-Tarp has an R-value of R-2 or less. For years, however, the manufacturer of Insul-Tarp claimed that the product was rated at R-7 or more. The blogger who specified Insul-Tarp believed the false claims, which is why he wrote, "This is what the Insul-Tarp looks like. The exterior is some kind of tough fabric, then there are two layers of thin white foam, then a layer of bubble wrap. Hard to believe this can be equivalent of 2 inches of styrofoam."Indeed, it is hard to believe — so hard, in fact, that the Federal Trade Commission initiated court action that forced Meyer Enterprises, the manufacturer of Insul-Tarp, to stop making false claims. According to the FTC complaint, Meyer Enterprises "claimed Insul-Tarp's R-value is 7.54, but in reality Insul-Tarp's R-value could not be more than 2."
Generally, unheated barns are healthier for your horses. Too much humidity will lead to unhealthy condensation, which can cause respiratory issues,...
Read More »
Start with a Switch The NEC requires a means, such as a single-pole switch, to disconnect the power where it enters the shed. ... Connect the wires...
Read More »
We typically prefer using PVC conduit when running power to a remote location underground. That gives you a lot more protection over direct burial...
Read More »
How to Deep Clean Your Garage Step 1: Remove Everything & Prepare your Supplies. ... Step 2: Sort, Eliminate, Donate or Sell. ... Step 3: Find...
Read More »