DIY Builds
Photo: Masha Raymers
The building code requires two layers, or equivalent, over wood-based sheathings when the cladding is a cementitious product; however, many consultants still advise that two layers are the best practice, even when not applied over wood-based sheathings.
Will a Fridge Work in a Cold or Unheated Garage? Very cold temperatures can interfere with your garage fridge's thermostat. If the temperature in...
Read More »
So, Can You Build a House Without a Foundation? The simple answer is that of course, you can — as long as you don't need it to stand for long....
Read More »
These are! They guide you every step of the way to complete your dream shed.
Learn More »
Older homes and high-end new homes will have plaster instead of drywall. Harder and more durable, plaster is also more expensive to install. In old...
Read More »
When you buy a compost toilet for camper or RV or tiny house you don't need to carry any special toilet paper. This system can break down the...
Read More »
High humidity can increase permeability rates of home wraps by as much as 12x A potential problem with building paper is that it has the ability to absorb water. This is a generally accepted fact being that the amount of water the paper will absorb varies from brand-to-brand, as well as by the age of the product, and any prior UV exposure before installation of the cladding system. When used as the outermost layer in a two-layer system with Tyvek® wrap as the innermost layer, the properties of the black paper may prove beneficial, especially when the cladding is an exterior cement plaster or adhered-masonry veneer. With Tyvek’s high permeability rate drying of the wall cavity is promoted. Some have raised concerns about the lower permeability of the asphalt-saturated paper blocking or impeding the vapor transmission. This is less of a problem than anticipated based on the way permeability rates are tested. Permeability rates are tested on the field of the membrane and do not take into account the laps and seams, which are numerous in the installation of an asphalt-saturated paper WRB. The ability of the asphalt-saturated paper to absorb moisture may allow it to act as a buffer between the exterior cement plaster and the Tyvek® wrap. With a vapor permeable membrane, the vapor can transfer in both directions, depending on the pressure differential. Vapor will drive from areas of high pressure to areas of low pressure; therefore, if the plaster is saturated and the wall cavity is dry, the drive could be from the wet plaster into the dry wall cavity. In this case, the lower perm paper may slow transmission from the plaster to the wall cavity. When the transmission is from the wall cavity to the exterior, the paper may absorb and hold the moisture until the plaster can dry enough to allow the vapor to transfer through it. However, if we install the two layers using the outer layer as a bond break layer and draining the flashings between these two layers as indicated in the IBC Section 2510.6 and further discussed in our Tech Alert on Flashing Integration, do we meet the requirement to protect wood-based sheathing with the equivalent of two layers of WRB? We would argue that unless the innermost layer is equal to two layers of Type I WRB that the sheathing is not properly protected. The building code does allow for an exception to the two layers where the WRB over the sheathing is equal to or greater than a 60-minute Grade D paper in its ability to resist water penetration and the stucco cladding is separated from this WRB by a substantially nonabsorbent layer or drainage space. To better understand why the manufacturer, consultant, or building code may want to separate the bond breaker from the air barrier, read our Tech Alert on Air Barrier Fundamentals. We recommend that you work with a building envelope consultant to determine which materials or combination of materials you will be using for your project’s building envelope. The installation of the building envelope is a high risk with the potential for damage and future litigation, and should be reviewed and inspected by a third-party quality assurance firm. Care should be taken to comply with codes, and to follow the best building science recommendations, while taking into consideration that the code is the minimum standard.
For a damp climate, a concrete slab foundation is better, but if your house rests on a flood-prone area or sees a lot of rain, a crawl space is...
Read More »
Myth No. 1: I need to redo my kitchen and bathroom before selling. Truth: While kitchens and bathrooms can increase the value of a home, you won't...
Read More »
A storage shed is a practical investment that can provide you and your future renters valuable storage space. Installing a quality shed can boost...
Read More »
If you do decide you can tackle a concrete slab, be sure to put a high-quality vapor barrier under the concrete. You don't want water vapor from...
Read More »
Saves Money: While a number of factors will determine the cost of your shouse, it'll likely be less expensive than a traditional house. A shouse...
Read More »
A home recording studio can cost you anywhere from $300 to $30,000 to set up. You can keep the costs at a minimum with a simple and basic setup,...
Read More »