DIY Builds
Photo: Nesrin Öztürk
Description: Scuppers are used to provide an outlet through parapet walls or gravel stops on flat and built-up roofs to allow drainage of excess water. They can be used in conjunction with gutters and downspouts to divert the flow to the desired location.
What NOT to Burn in your Fireplace or Wood Burning Stove Painted or varnished wood, trim or other wood by-products. Pressure-treated lumber – due...
Read More »
Cardboard does not actively absorb sound, but the material will significantly reduce the transfer of noises and echoes when placed along walls,...
Read More »Description: Scuppers are used to provide an outlet through parapet walls or gravel stops on flat and built-up roofs to allow drainage of excess water. They can be used in conjunction with gutters and downspouts to divert the flow to the desired location. Scuppers can be installed to carry water into gutters or directly into downspouts through conductor heads. When a conductor head is used, it should be at least 2" wider than the scupper. When neither conductor heads nor gutters are used to catch the water, scupper spouts should extend past the exterior surface of the building to avoid wetting the building surface. The minimum recommended weight for the construction of scuppers is 16 oz. copper. Scuppers are fabricated with flanges on the roof side which extend 4" onto the roof. Wood blocking is required under scuppers to provide a nailable surface. Scuppers should be spaced no greater than 10 feet apart depending on the roof area drained. Special Conditions: In areas with severe ice and snow conditions and/or excessive debris, conductor heads with overflow openings should be used. Where a roof is completely surrounded by parapet walls and drainage is provided by scuppers or internal drains, overflow scuppers should be provided. The roof-side flange of the gravel stop is nailed at 3" O.C. to the perimeter blocking. 10.5A. Scupper at Raised Roof Curb This detail illustrates the installation of a scupper through a raised roof curb with a gravel stop. Since no gutters or conductor heads are provided, the scupper spout should extend beyond the exterior face of the building. Download CAD File All joints of the scupper should be soldered. The edge of the copper fascia and gravel stop at the scupper should also be soldered. 10.5B. Scupper at Gutter This detail shows a scupper used in conjunction with a gutter. The scupper spout is soldered into the copper fascia and gravel stop. Download CAD File The drip edge of the fascia should extend over the back edge of the gutter by 1" minimum. The scupper and gravel stop flanges are nailed to the blocking. The gutter should be allowed to move independently of the fascia/gravel stop. 10.5C. Scupper at Conductor Head The conductor head must be at least 2" wider than the scupper. It is attached to the wood nailer through the fascia. The scupper spout is locked and soldered to the conductor head. All joints between scupper, conductor head, downspout, fascia and gravel stop are soldered. Download CAD File The minimum weight of copper suitable for conductor heads is 16 oz.
Roofing material that lasts the longest are concrete, clay or slate tiles. These materials significantly outperform other natural products like...
Read More »
Unlike an extension or conservatory, when you choose a pergola or patio canopy you don't need to apply for planning permission or adhere to...
Read More »10.5D. Scupper at Parapet Wall Shown is the installation of a copper scupper through a parapet wall in conjunction with conductor head and downspout. Download CAD File Download CAD File The conductor head is attached to the exterior wall using masonry fasteners. The scupper spout is locked and soldered onto the back edge of the conductor head. If conductor heads without overflow are used, the rim of the head should be set 1" below the scupper. A closure flange is inserted and sealed into a masonry joint above the scupper. The sides are also sealed against the masonry. The scupper is locked and soldered onto the flange at the top and two sides. On the roof side, the flange is covered by copper flashing. The flange is formed and soldered to the roof side of the scupper, leaving at least 4" of material around the opening. A continuous sheet of copper counterflashing is inserted into a masonry joint above this flange. This flashing extends at least 2" beyond the ends of the flange and laps the soldered joint between the flange and the scupper. The bottom edge of the scupper on the roof side is locked and soldered into a continuous copper cleat. A copper gravel stop is soldered in the scupper.
Put Landscaping Fabric or Plastic Down First This problem can get especially challenging with flower beds. Landscaping fabric or plastic serves as...
Read More »
3-5 years Wooden pallets struggle to withstand humid environments and harsh weather conditions. They crack, splinter, and absorb water – causing...
Read More »
Most shop homes are made of steel because of the low cost and easy assembly. You can buy shop house kits that are pre-made and delivered right to...
Read More »
acrylic latex paint The best type of paint to use on sheds is a premium quality, 100% acrylic latex paint, such as Sherwin Williams A-100 exterior...
Read More »