DIY Builds
Photo: Blue Bird
for 300 feet for 100 amp rated service I would use Aluminum direct burial 1/0-1/0-1/0-1/0, the forth can be as low as #4 for the ground (but also in conduit, even if in conduit must still be rated underground wire and required by code also) Also note the size wire the breaker can handle, cannot cut strands to make fit, ...
Because the Blue Rose is the rarest color of rose, you can expect the price of the flower to be higher than other colors. Due to the fact that the...
Read More »
concrete garage apron The concrete garage apron is the concrete slab in front of the garage door. The apron is usually between 2 to 6 feet wide and...
Read More »So for anyone finding this page, none of the answers are incorrect or be qualified electrician. please for any electric services needed find and ask a qualified electrician. Basically the breaker size protects the wire, So the breaker should not be higher amperage than the wire rating, however can over size the wire to meet voltage drop requirements. load calculations are for what minimum size panel/service needed but not the actual service rating if the breaker from the service side is a 100amp breaker feeding this then wire rated for 100 amp, etc. Most ampacity charts are up to 100 feet and go up one size of additional 100 feet. So, if using a 100amp breaker at the service side, then need to minimally size the wire accordingly and there are different rating for non burial, burial and in conduit Aluminum sizes will be larger than copper. For that service would use URD Aluminum 4 conductor cable (need 2 hot, neutral and should have separate ground to shop, grounds isolated from neutrals in shop panel. for 300 feet for 100 amp rated service I would use Aluminum direct burial 1/0-1/0-1/0-1/0, the forth can be as low as #4 for the ground (but also in conduit, even if in conduit must still be rated underground wire and required by code also) Also note the size wire the breaker can handle, cannot cut strands to make fit, no no no, so check the breaker specs first. So if not really needing full 100 amp load, can go down smaller wires sizes, but use smaller breaker to meet the maximum amperage rating for that wire. so for example could use a popular 2-2-2-4 URD Aluminum direct burial wire, but would only use a 60 amp breaker for that distance, 80 amp if needed but could experience some voltage drop at high load, bad for running motors any length of time. Copper would allow smaller wire size, bigger wire still fit into breaker but is way more expensive. best to google look at a few wire size charts better contact an actual qualified electrician.
And if you're looking to trick out your shed with a wet bar or convenient bathroom? Plumbing is an even more costly addition, starting at $1,000 to...
Read More »
Barn (also known as gambrel style) Anytime you take a cruise on a country road, you will find wood barn sheds.
Read More »
The average cost to renovate a whole 1,200 sq. ft. house is $18,000 to $72,000, while remodeling a 2,000 sq. ... Whole house renovation cost....
Read More »
Only when your shed is to be located in an area that is below the grade of the rest of your yard should a concrete pad be considered for extra...
Read More »
These are! They guide you every step of the way to complete your dream shed.
Learn More »
Rebar should be placed in every other masonry core to provide structural support. For masonry cores over 4 inches wide, QUIKRETE Core Fill Grout –...
Read More »
What handmade wood items sell best? Wooden signs. Wall signs. Wooden pallets. A wooden bench. Kitchen products. Furniture. Surfboards. Boxes. More...
Read More »