Why is Romex not allowed in conduit?

one reason you don't put romex in conduit is because it creates more heat and is not advised in conduit if you have conduit you can run insulated wires instead it's probably cheaper. when you put romex inside conduit The Romex cannot breathe and retains too much heat.

What do you cover the bottom of a shed with?
What do you cover the bottom of a shed with?

Shed skirting options include a wide range of materials that vary in aesthetics, including vinyl siding, brick, chicken wire, faux stone veneer,...

Read More »
Will painting over rust stop it?
Will painting over rust stop it?

Paint is the shield between the iron in the metal and the oxygen and moisture in the environment. By coating your metal with paint, you'll prevent...

Read More »
Are shed plans easy to follow?
Are shed plans easy to follow?

These are! They guide you every step of the way to complete your dream shed.

Learn More »

In addition to Tester101's excellent answer on when NM-B can be run through conduit, there is a section in the NEC which indirectly prohibits running NM-B through conduit in specific scenarios: From the 2014 NEC: 312.5 Cabinets, Cutout Boxes, and Meter Socket Enclosures. Conductors entering enclosures within the scope of this article shall be protected from abrasion and shall comply with 312.5(A) through (C). (C) Cables. Where cable is used, each cable shall be secured to the cabinet, cutout box, or meter socket enclosure. Exception: Cables with entirely nonmetallic sheaths shall be permitted to enter the top of a surface-mounted enclosure through one or more nonflexible raceways not less than 450 mm (18 in.) and not more than 3.0 m (10 ft) in length, provided all of the following conditions are met: (a) Each cable is fastened within 300 mm (12 in.), measured along the sheath, of the outer end of the raceway (b) The raceway extends directly above the enclosure and does not penetrate a structural ceiling. (c) A fitting is provided on each end of the raceway to protect the cable(s) from abrasion and the fittings remain accessible after installation. (d) The raceway is sealed or plugged at the outer end using approved means so as to prevent access to the enclosure through the raceway. (e) The cable sheath is continuous through the raceway and extends into the enclosure beyond the fitting not less than 6 mm (1⁄4 in.). (f) The raceway is fastened at its outer end and at other points in accordance with the applicable article. (g) Where installed as conduit or tubing, the cable fill does not exceed the amount that would be permitted for complete conduit or tubing systems by Table 1 of Chapter 9 of this Code and all applicable notes thereto. Informational Note: See Table 1 in Chapter 9, including Note 9, for allowable cable fill in circular raceways. See 310.15(B)(3)(a) for required ampacity reductions for multiple cables installed in a common raceway. The fittings used with NM cable to enter a breaker panel also secure the cable to the panel. When conduit is used, I am not aware of another approved method to secure the cable to the breaker panel as required for conduit runs longer than 10 ft. So practically speaking, you cannot have an entire run of NM-B (or any other non-metallic sheathed cable assembly) enclosed in conduit from a breaker panel because it then limits you to a maximum length of 10ft from a surface-mounted cabinet, cutout box, or meter socket enclosure (including breaker panels/boxes in their definitions). The only direction that NM-B can exit the panel in conduit is out of the top of the panel. The conduit for runs attached directly to the surface-mounted panels also have to be a nonflexible conduit per this clause as well. I believe flexible conduit is out of the picture because it offers no protection from physical damage anyways and that is the primary practical reason to run NM-B in conduit, so you might as well be directly attaching the cable to the breaker panel. This clause also implies that runs of NM-B fully enclosed in conduit attached to a recessed-mount panel are prohibited. I believe this is the same reason that non-flexible conduit is not specified because NM-B should be protected from damage by the wall covering anyway for a recess-mount panel and there is no longer need for non-flexible raceways to protect the cable.

What is the cheapest source of heating a home?
What is the cheapest source of heating a home?

Air conditioning. Based on running costs alone, reverse-cycle air conditioning is by far the cheapest way to heat your home: our estimates show...

Read More »
Can you put a metal building on a wood foundation?
Can you put a metal building on a wood foundation?

Depending on the size of your metal building, gravel, dirt, wood, or concrete are all viable options for a functional foundation. Ideally, your...

Read More »

What is the disadvantage of PVC in underground installation?

Disadvantages of plastic pipes: Due to their non-decomposing property, plastic pipes are not installed in high temperature. They are easily cracked. At higher temperatures, the strength of plastic pipes reduces.

Once your home construction work is completed, the second step is to install the piping network. The choice of piping materials determines the type of installation as well as required maintenance. When it comes to choosing the piping materials, PVC pipe is the first choice for many people.

PVC piping is used for:

Drain-waste-vent (DWV).

Sewers.

Water mains.

Water service lines.

Irrigation.

Conduit.

Various industrial installations.

PVC pipe system can be produced in a lot of colors and you could easily recognition it after take a look:

White for DWV and some low pressure applications.

White, blue, and dark gray for cold water piping.

Green for sewer service.

Dark gray for industrial pressure applications.

Plastic pipes are light in weight, tough, resistant to chemical attack and available in large lengths.

They reduce the cost of handling, transportation and installation.

Less number of joints facilitates the speed and reduces chances of leakage.

They are rust resistant.

These pipes have good elastic properties.

Their adaptability to earth movements is superior.

Smooth internal surface of the pipes offer less friction.

Due to less friction it saves the energy in the conveyance of water.

Disadvantages of plastic pipes:

Due to their non-decomposing property, plastic pipes are not installed in high temperature.

They are easily cracked.

At higher temperatures, the strength of plastic pipes reduces.

If you are looking to buy the PVC pipe Ajay is the best option. Their price is also very reasonable. If you want to know more about PVC Plumbing pipes and having any doubts about it then call at our toll-free customer care executive at : 1800 114 050 for any Query .Their price is also very reasonable. For more info visit http://www.ajaypipes.com/

Is it OK to water plants before a freeze?
Is it OK to water plants before a freeze?

Drought-stressed plants are more susceptible to cold damage, so watering plants a few days in advance of a cold snap is beneficial. Watering just...

Read More »
Does overhang count as square footage?
Does overhang count as square footage?

In some municipalities, vaulted ceilings will double the square footage of a room. In other places, porches, overhangs and pergola areas will count...

Read More »
How long should you wait to split wood?
How long should you wait to split wood?

six months 4. Let the wood dry at least six months and preferably longer. The hardest lesson: firewood takes a very long time to season Most folks...

Read More »
How much does it cost to build a shed with electricity?
How much does it cost to build a shed with electricity?

Electrical materials will cost around $150 to run a line from your house to a shed 50 feet away. But unless you have this specific skill set,...

Read More »